Specifications
| 
						 Detectable Gases  | 
				|||||
| 
						 Gas  | 
					
						 Measuring Range  | 
					
						 Accuracy  | 
					
						 Preset Alarms  | 
				||
| 
						 Sensor Slot 1: Carbon Monoxide (CO) & Hydrogen sulfide (H2S) *Interchangeable  | 
				|||||
| 
						 H2S / CO  | 
					
						 Dual EC  | 
					
					   0 ~ 2000 ppm  | 
					
					   ± 5% of reading  | 
					
					   A1: 25 ppm│ A2: 50 ppm  | 
				|
| 
						 0 ~ 200.0 ppm  | 
					
					   ± 5% of reading  | 
					
					   A1: 5 ppm│ A2: 30 ppm  | 
				|||
| 
						 H2S  | 
					
						 EC  | 
					
					   0 ~ 200.0 ppm  | 
					
					   ± 5% of reading  | 
					
					   A1: 5 ppm│ A2: 30 ppm  | 
				|
| 
						 CO  | 
					
						 EC  | 
					
					   0 ~ 2,000 ppm  | 
					
					   ± 5% of reading  | 
					
					   A1: 25 ppm│ A2: 50 ppm  | 
				|
| 
						 Sensor Slot 2: Combustibles (Methane as standard)  | 
				|||||
| 
						 CH4 / HC  | 
					
						 Catalytic  | 
					
					   0 ~ LEL (1% LEL)  | 
					
					   ± 5% of reading  | 
					
					   1st: 10% LEL │ 2nd: 25% LEL  | 
				|
| 
						 Sampling Method  | 
					
						 Diffusion sampling standard (hand aspirator or clip-on motorized pump optional)  | 
				|||||
| 
						 Display  | 
					
						 Digital LCD displays with 7 segment plus 14 segment plus icon  | 
				|||||
| 
						 Preset Alarms        | 
					
						 1st alarm:                           25.0 ppm  | 
					
						 1st alarm:                                             5.0 ppm  | 
					
						 1st alarm:                 10% LEL  | 
				|||
| 
						 Types of Alarms  | 
					
						 Gas Alarm:		3 Increasing alarms, STEL, TWA, overscale alarm. O2 decreasing/increasing.  | 
				|||||
| 
						 Display of Alarm  | 
					
						 Gas Alarm:		Flashing LEDs, continuous buzzer (100 db @ 30 cm), flashing gas value, vibration   | 
				|||||
| 
						 Operating Temp.   | 
					
						 -20°C ~ +50°C [ -4°F ~ +122°F ], 10 to 90% RH, non-condensing (continuous environment)  | 
				|||||
| 
						 Response Time  | 
					
						 Within 30 seconds (T90)  | 
				|||||
| 
						 Power Source  | 
					
						 Lithium-ion battery, Approx. 25 hours after a 3 hour full charge  | 
				|||||
| 
						 Approvals  | 
					
						 ATEX, CSA (Pending)  | 
				|||||
| 
						 Dimension   | 
					
						 2.2” W x 2.55” H x 1.02” D (Approx. 58 W x 65 H x 26 D mm), 3.52 ounces (approx. 100 g) without rubber booth  | 
				|||||
| 
						 Case Material  | 
					
						 Explosion proof, dust and water resistant to IP-66/68 (2m,1h) approval. Drop height 23 ft  | 
				|||||
| 
						 Controls  | 
					
						 Two buttons: POWER / MODE, AIR  | 
				|||||
| 
						 Datalogging  | 
					
						 Logs user ID, station ID, Calibration & Bump Test history, Alarm Events & Alarm Interval Trends  | 
				|||||
| 
						 Standard   | 
					
						 Alligator clip, protective rubber boot, charger, and calibration adapter  | 
				|||||
| 
						 Optional   | 
					
						 SDM-3R calibration station  | 
				|||||
| 
						 Warranty  | 
					
						 Three years material and workmanship  | 
				|||||
| 
						 Detectable Gases  | 
				|||||
| 
						 Gas  | 
					
						 Measuring Range  | 
					
						 Accuracy  | 
					
						 Preset Alarms  | 
				||
| 
						 Sensor Slot 1: Carbon Monoxide (CO) & Hydrogen sulfide (H2S) *Interchangeable  | 
				|||||
| 
						 H2S / CO  | 
					
						 Dual EC  | 
					
					   0 ~ 2000 ppm  | 
					
					   ± 5% of reading  | 
					
					   A1: 25 ppm│ A2: 50 ppm  | 
				|
| 
						 0 ~ 200.0 ppm  | 
					
					   ± 5% of reading  | 
					
					   A1: 5 ppm│ A2: 30 ppm  | 
				|||
| 
						 H2S  | 
					
						 EC  | 
					
					   0 ~ 200.0 ppm  | 
					
					   ± 5% of reading  | 
					
					   A1: 5 ppm│ A2: 30 ppm  | 
				|
| 
						 CO  | 
					
						 EC  | 
					
					   0 ~ 2,000 ppm  | 
					
					   ± 5% of reading  | 
					
					   A1: 25 ppm│ A2: 50 ppm  | 
				|
| 
						 Sensor Slot 2: Combustibles (Methane as standard)  | 
				|||||
| 
						 CH4 / HC  | 
					
						 Catalytic  | 
					
					   0 ~ LEL (1% LEL)  | 
					
					   ± 5% of reading  | 
					
					   1st: 10% LEL │ 2nd: 25% LEL  | 
				|
| 
						 Sensor Slot 3: Oxygen (O2)  | 
				|||||
| 
						 O2  | 
					
						 EC  | 
					
					   0 ~ 40.0% Vol.  | 
					
					   ± 0.5% O2  | 
					
					   Low 1: 19.5%│ Low 2: 18.0%  | 
				|
| 
						 Sensor Slot 4: Toxics & CO2 *Interchangeable  | 
				|||||
| 
						 SO2  | 
					
						 EC  | 
					
					   0 ~ 100.0 ppm  | 
					
					   ± 10% of reading  | 
					
					   A1: 2 ppm│ A2: 5 ppm  | 
				|
| *CO2 IR sensor available AUG 2019 | |||||
| 
						 CO2 %  | 
				  
				     IR*  | 
					
					   0 ~ 10.0% Vol.  | 
				  
				     ± 5% of reading  | 
					
					   A1: 0.50% Vol.│ A2: 3.00% Vol.  | 
				|
| 
						 CO2 ppm  | 
					
						 0 ~ 10,000 ppm  | 
					
					   A1: 5,000 ppm│ A2: N/A  | 
				|||
| 
						 Common Specifications  | 
				||||
| 
						 Sampling Method  | 
					
						 Diffusion sampling standard   | 
				|||
| 
						 Display  | 
					
						 Full dot LCD with Autobacklight   | 
				|||
| 
						 Alarm Types  | 
					
						 Gas Alarm  | 
					
						 Trouble Alarm  | 
				||
| 
						 • 2 increasing        | 
					
						 • Sensor   | 
				|||
| 
						 • Man Down Alarm  | 
				||||
| 
						 Display of Alarm  | 
					
						 Gas Alarm  | 
					
						 Trouble Alarm  | 
				||
| 
						 • Flashing   | 
					
						 • Flashing   | 
				|||
| 
						 Operating Temp. & Humidity  | 
					
						 -20°C ~ +50°C   | 
				|||
| 
						 -40°C ~ +60°C   | 
				||||
| 
						 Response Time  | 
					
						 Within 30 seconds (T90)  | 
				|||
| 
						 Power Source  | 
					
						 Config  | 
					
						 Li-ion  | 
					
						 Alkaline  | 
				|
| 
						 4-gas + EC  | 
					
						 25 hours  | 
					
						 16 hours  | 
				||
| 
						 4-gas + IR  | 
					
						 16 hours  | 
					
						 7 hours  | 
				||
| 
						 Dimension & Weight  | 
					
						 2.9” W x 2.6” H x 1.06” D   | 
				|||
| 
						 Case Material  | 
					
						 Explosion proof, dust and water resistant to IP-66/68 (2m,1h) approval. Drop height 23 ft  | 
				|||
| 
						 Bluetooth Communication  | 
					
						 BLE: with iOS and Android phone app: RK Link  | 
				|||
| 
						 Datalogging  | 
					
						 Logs user ID, station ID, Calibration & Bump Test history, Alarm Events &   | 
				|||
| 
						 Standard Accessories  | 
					
						 Alligator clip, protective rubber boot, charger, calibration adapter  | 
				|||
| 
						 Optional Accessories  | 
					
						 • Padded carrying case  | 
				|||
| 
						 Safety Design / Approvals  | 
					
						 ATEX, CSA (Pending)  | 
				|||
| 
						 Warranty  | 
					
						 Three years material and workmanship including sensors  | 
				|||
| *specifications subject to change | ||||
| 
 Input Power  | 
AC Adapter with 100 - 240 VAC, 47/63 Hz, 0.4A input and 5.99 VDC, 2A output provided as standard. | 
| 
 Environmental Conditions  | 
• For Indoor Use Only • -10° C to 40° C, below 95% Relative Humidity, Non-Condensing | 
| 
 Applicable Instruments  | 
GX-3R and GX-3R Pro | 
| 
 Maximum Number of Records Saved  | 
  | 
| 
 5 Ports  | 
3 Calibration gas, 1 fresh air and 1 exhaust | 
| 
 Standard Accessories  | 
  | 
| 
						 Pump Specifications  | 
				|
| 
						 Flow Rate  | 
					
						 Higher flow mode: 0.5 l/m Lower flow mode (ECO mode): 0.35 l/m  | 
				
| 
						 Alarm Display  | 
					
						 Low flow alarm: Flow blinks YELLOW Low battery alarm: Power LED blinks GREEN  | 
				
| 
						 Power Supply  | 
					
						 1 AA alkaline battery  | 
				
| 
						 Continuous Operation  | 
					
						 Higher flow mode: 10 hours Lower flow mode (ECO mode): 16 hours  | 
				
| 
						 Operating temperature  | 
					
						 -4° F to + 122° F (no sudden change)  | 
				
| 
						 Operating humidity range  | 
					
						 95% RH or less (without condensation)  | 
				
| 
						 External Dimensions  | 
					
						 3.23" (W) x 3.78" (H) x 1.14" (D) (body only)  | 
				
| 
						 Weight  | 
					
						 4.58 oz  | 
				
| 
						 Explosion Proof  | 
					
						 Intrinsically safe construction (Exia II CT 4 Ga) pending  | 
				
| 
						 Standard Accessories  | 
					
						 4" tapered red rubber nozzle, AA alkaline battery,  | 
				
| 
						 Optional Accessories  | 
					
						 10' - 100' hose, 10" probe with dust filter  | 
				